Static Var Generator SVG50/70/100/150KVAR


所属分类:

Power Quality Series

Product Center

Power quality Modules

Static Var Generator(SVG)

Product function
Improve Power Factor PF > 0.99
Reactive Power Compensation
Compensated inductive or capacitive reactive
Unaffected by harmonics

    • Wall Mounted Wall Mounted
    • Rack Mounted Rack Mounted

Tel/Wechat/Whatsapp:

Quantity
-
+

库存剩余

1100

隐藏域元素占位

编号 :

AHF05

undefined
undefined
undefined
undefined
undefined
+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined
  • Description
    • Commodity name: Static Var Generator SVG50/70/100/150KVAR
    • Commodity ID: AHF05

    <p><strong>Product function</strong><br /> Improve Power Factor PF > 0.99<br /> Reactive Power Compensation <br /> Compensated inductive or capacitive reactive<br /> Unaffected by harmonics

    Product Description

    Static Var Generator (SVG) is a product aimed for Power Factor Correction, Voltage Regulation along with Three-phase Balancing Function. SHHKK-SVG can do bi-directional power factor correction, PF from 1.0 inductive to 1.0 capacitive. Benefiting from inverter technology, SVG compensation is stepless, which means SVG output shall match the system reactive power, no over-compensation or under compensation. For single module, SVG capacity ranges from 35kvar to 120kvar. For cabinet system, it's unlimited parallel design . 
    Compared with the traditional capacitor bank, SVG has the advantages of fast response and high compensation accuracy without under-compensation or over-compensation problems.

    Product model and meaning



    Technical parameters
     

    Standard type 400V 400V 480V 690V
       35kyar 50kvar 75kya 100kyar 150kyar 90kyar 120kvar
    System parameters
    R.atedinput wire vdltage 380V(-15%~+20%) 380V(20%~+20%) 480V(-20%~+20%) 690V(-30%~+15%)
    Grid frequency 50/60Hz(range:45Hz~63Hz)
    Number of parallel machines 1~10sets
    Overallefficiency ≥97% ≥98%
    Grid structure Three-phase three-wire/three-phase four-wire Three-phase three-wire
    Current transformer 150/5~10000/5
    Circuit topology Tri-level
    Performance index
             Single  module
    compensation  capac  ity
    35kvar 50kvar 75kvar 100kvar 150kvar 90kvar 120kyar
    Response time <15ms <20ms
    Scope of compensation From-1 to 1.capacitive and inductive continuity is adjustable
    Cooling mode Intelligent air cooling
    Noise index <56dB <65dB
    Communication monitoring ability
    Communication interface Rs485,internet access
    Communication protocol Modbus Protocol,General Electric Protocol,TCP/IP
    Fault alarm Yes,up to 256 alarm records
    Monitoring mode Support centralized monitoring and independent monitoring
    Mechanical characteristic
    Fived mode Rack type,wall-mounted type Rack type
    Incoming line mode Rack-type back-incoming line
    wall-mounted up-incoming line
    Back-incoming line
    Appearance color National Standard 7035-Light Grey(Customizable)
      National Standard 7035-Light Grey (Customizable)
    Altitude (1500m, used in accordance with rated capacity; 1500-5000m, used according to GB/T 3859.2
    reducing rated capacity by 1% for each increase of 100m,
    Operating temperature -25~40'℃
    Relative humidity 5%~95%,no condensation
    Grade of protection IP20


    Working prin ciple

    HKK-SVG static var generator is a bridge converter composed of fully controlled power ele ctronic devices for dynamic reactive compensation, The basic principle is that the load current is detected in rea time by the externa current transtormer 1CT). and the reactive content of load current is extracted bythe internalDSP computing. Finally, the instruction value is calculated to control the PWM signal generator to send the control signal to the internal lGBT, so that the inverter can produce the reactive compensation currentto meetthe requrement, and finally real ize the dvnamic reactive compensation

    1. HKK-SVG compensates capacitive var (vector graph)



    2.HKK-SVG compensation for inductive var (vector graph)



    3. HKK-SVG schematic diagram



    4. The compensation effect before and after the use of Hkk-SVG is shown in the picture
    a. Voltage and current before the analog device is put into operation




    b. Reactive current emitted by the analog device



    C. The compensation effect after the analog device is put into operation



    The essential improvement of the var compensation effect of HKK-SVG
     

    Traditional compensation device HKK-SVG static var generator
    HKK-SVG is a component device and can be assembled freely,but TSC
    compensation device switching capacitor group is grouped switching
    the reactive power outputcapacity is stepped compensation capacity
    which can not be adjusted continuously,it is difficult to achieve balance
    completely with the reactive power of the system,which iseasy to cause
    over complement or under-compensation,the compensated power
    factor is generally around 0.8-0.9.
    HKK-SVG adopts the design concept of component-based
    products,which can compensate the capacitive and inductive
    loads,achieving the level 0.99 compensation effect,and
    avoiding the situation of overcompensating and
    under-compensating
     It takes up to 20 milliseconds for a traditional compensation
    device to complete the compensation
    The complete response time of HKK-SVG is less than 15
    milliseconds,and the dynamic response time is less than
    50 microseconds,especially suitable for fast changing
    situations.
    The traditional compensation device uses SCR-regulated
    reactance plus multi-group LC as the main means of var
    compensation,which is easy to produce resonance
    amplification and leads to safety accident.
    HKK-SVG capacitors do not need to set up filter banks,there
    is no resonance amplification;and HKK-SVG is an active
    compensation device,is a current active device composed
    of a detachable device IGBT,the resonance phenomenon
    is avoided in mechanism and the safety is greatly improved.
    The traditional compensation device uses capacitor to provide
    var power,which can only compensate the inductive load,
    and loses the compensation effect when the system is
    capacitive or in the state of capacitive and inductive

    repeated changes.
    HKK-SVG can adjust var power dynamically,bidirectionally
    (-1~1)continuously,that is,it can output var continuously
    from rated inductive condition to rated capacitive condition
    and it,combined with fixed capacitor,can form any range
    of continuous compensation.
    Traditional compensation devices usually require high-capacity
    capacitors and reactors as energy storage components,so
    they occupy a large area of space.
    HKK-SVG does not need large capacity capacitors and reactors
    to do energy storage components,the area is usually only 50%
    of the same capacity of other types of dynamic compensation,
    or even smaller,while HKK-SVG uses modular design and
    cabinet installation,workload of engineering design and
    installation is small.
    Traditional compensation devices rely on capacitors to provide
    capacitive var.Because the output reactive current is
    proportional to the grid voltage,if the grid voltage is low
    the output reactive current is also low,resulting in a
    decrease in the compensation capacity,it is difficult for them to
    provide adequate compensation
    HKK-SVG adopts active compensation circuit,the
    compensation capacity is little affected by the system voltage
    and can output reactive current similar to the rated condition
    when the system voltage is low.
    The traditional compensation device has frequent
    compensation switching,short service life,usually in three
    years or so,and needs to be maintained frequently.
    HKK-SVG has minimal loss and doesn't need maintenance
    basically,and there is no resonance overvoltage problem
    the design life is more than ten years with normal use
    and trouble-free.
    To achieve better compensation effect,the traditional
    compensation device usually requires the installation
    capacity to be greater than the compensation capacity
    The compensation capacity is installation capacity,when
    reaching the same compensation effect,the capacity can
    be 20%-30%smaller than the capacity of the traditional
    compensation device.